Skip to main content

Table 4 Comparison of FE-calculated natural frequencies and [1]

From: Application of machine learning procedures for mechanical system modelling: capabilities and caveats to prediction-accuracy

Frequency

FE-Analysis Calculix

Marwala measured

Marwala model

Hz

Hz

Hz

\(F_1\)

41.14

41.5

42.3

\(F_2\)

113.54

114.5

117.0

\(F_3\)

126.22

N/A

N/A

\(F_4\)

222.75

224.5

227.3

\(F_5\)

346.58

N/A

N/A

\(F_6\)

368.31

371.6

376.9