Table 4 Comparison of FE-calculated natural frequencies and [1]

From: Application of machine learning procedures for mechanical system modelling: capabilities and caveats to prediction-accuracy

FrequencyFE-Analysis CalculixMarwala measuredMarwala model
HzHzHz
\(F_1\)41.1441.542.3
\(F_2\)113.54114.5117.0
\(F_3\)126.22N/AN/A
\(F_4\)222.75224.5227.3
\(F_5\)346.58N/AN/A
\(F_6\)368.31371.6376.9